H10-120K Series Online UPS (3 Ph in 3 Ph out)
H10K-120K series online UPS designed to meet the needs of SMEs with low investment costs, sustainable operating cost savings, high reliability, and fast and flexible adaptation.
Key Features
Parameter

Reliable, efficient, flexible and easy to use

This UPS solution designed to meet the needs of SMEs with low investment costs, sustainable operating cost savings, high reliability, and fast and flexible adaptation.

 

Advantage

Double IGBT technical, input PFC>0.99, THDI<3%.

Efficiency up to 96.5% with three-level technology.

Big charger power up to 15% of total power.

Intelligent LCD screen support 12 languages, such as English, Russian, Spanish, French, Korean, Italy, Turkish.

The internal air channel is designed in such a way that internal hot air drives directly towards the heat sink, without distressing the PCBs and other internal sensitive circuits.

High-frequency UPS for small and medium-sized applications, with the best flexibility and reliability in the industry

Efficient power protection solutions optimize your initial investment and late operating costs. Our latest ECO Mode is more than 99.1% efficient, while Online Mode is 96.5% efficient. Flexible UPS configurations help customers devel op the ideal solution to help businesses achieve superior performance at lower total operating costs and meet stringent service agreement requirements.

Reliability is a core advantage of this UPS, with a robust architecture that can easily handle input failures, load failures, transient overload, and input power interference for use in light industrial production environments.

High efficiency system

Improving energy efficiency has become a common demand in all walks of life. so many manufacturers have timely introduced efficient UPS system. However, they ignore load efficiency under ordinary working conditions.

In most cases, the efficiency declared by UPS manufacturers is the data under full load, but in fact the system rarely runs at full load. By comparing efficiency, you can accurately predict operating costs. This is a unique feature of the UPS.

It can continuously achieve more than 99% efficiency in ECO mode. And the efficiency is still the same in the parallel configuration. There is no need to install external accessories. So it can save high initial year With industry-leading, efficient technology, it minimizes emissions and helps data centers meet industry environmental and efficiency standards.

Flexible configuration and easy maintenance

Easy maintenance

Modular design for more flexible replacement

Minimal installation space

Unit-level maintenance

DC capacitor, AC capacitor module can be replaced independently

Component-level Protection

One power unit per phase to prevent failure expansion.

IGBT and driver board adopt electromagnetic shielding to enhance protection and improve reliability.

 

High reliability

This UPS is designed to maximize the safety and reliability of power supplies and leverage industry experience and expertise to achieve UPS solutions with high MTBF and low MTTR through a comprehensive service design.

The charger power of this UPS can reach 15% of the rated power of the UPS. Even if the battery backup capacity is large, the sufficient charging power can be guaranteed.

The reliability of UPS is determined by many factors. But the most important thing is that it uses a solid internal architecture design which can flow the hot air generated by it only through the heat sink without affecting the PCB and other internal sensitive circuits. This function extends device life, prevents premature failure and achieves highest reliability.

Maintainability

Although there are many repair companies that can provide basic repair and maintenance services, the services provided by SOPOWER can take critical maintenance activities to a new level: proactive maintenance, which can greatly extend the life of the power supply system.

Customer monitoring interface

Combine intelligent and intuitive interfaces, system monitoring, and DCIM solutions to infrastructure in the best performance from the start to finish.

Human-computer interface: An information-rich LCD interface, equipped with user-friendly graphics display, to help customers achieve comprehensive monitoring, effectively reduce human error.

Provides a single-line operating chart with clear system conditions.

Hardware interface: Support for multiple communication protocols for UPS monitoring: UPS and building monitoring and automation systems can be integrated into one-body via MODBUS RTU MODBUS/TCP protocol, support dry contact communication.


Output 380V/400V415VAC


ModelStandard UnitH10K3H20K3H30K3H40K3   
Long Run UnitH10K3-XLH20K3-XLH30K3-XLH40K3-XLH50K3-XLH60K3-XLH80K3-XLH100K3-XLH120K3-XL
Nominal Rating (KVA)10K20K30K40K50K60K80K100K120K
Input
Nominal Input   voltage (V)380/400/415
Input Voltage Range   (V)228-478
Nominal Input   Frequency (Hz)50/60
Input Frequency   Range (Hz)40-70
Bypass Voltage   Tolerance (%) Upper limit: +10%, +15%, or +20% default:   +15%;
    Lower limit: -10%, -20%, -30% or -40% default: -20%
Bypass Frequency   Tolerance (%) ±10% or ±20%, default: ±10%
Input Power Factor> 0.99
Current THD at full   Linear Load (Thdi%)< 3%
Battery
Battery   VoltageStandard Unit30pcs
    12V 7AH
30pcs
    12V 7AH
60pcs
    12V 7AH
64pcs
    12V 7AH
   
Long Run Unit±192V ~ ±264Vdc, battery quantity 32-44 pcs (optional)
Temperature   Compensation (mV/℃/Cell)- 3.0 (selectable from 0 to -5.0 around 25℃ or 30℃, or inhibit)
Battery Charger   Current (A)0-20 (adjustable)0-40 (adjustable)
Output
Nomminal Output   Voltage (V)380/400/415
Nominal Output   Frequency (Hz)50/60
Output Power Factor111110.9110.9
THDv with 100%   Linear Load (%)<1%
Inverter Overload   Capactiy110% for 60min, 125% for 10min, 150% for 1 min
Efficiency
Online Mode   EfficiencyUp to 96.5%
ECO-Mode EfficiencyUp to 99.1%
Parallelparallel up to 6 units
Physics Characteristic
Dimensions
    (WxDxH) mm
Standard Unit300x700x1105300x810x1260   
Long Run Unit300x700x800360x800x980
Weight   (KG)Standard Unit146146194198   
Long Run Unit747474757575115116118
General
Noise at 1m dB(A)<55dB (1 meter away) <60dB (1 meter away) 
Altitude≤ 1500, derate power by 1% per 100m between 1500m and 300m
VentilationFront to back standard
Protection LevelIP20
General and SafetyEN62040-1/IEC62040-1
EMC StandardsEN62040-2 / IEC62040-2
Method   of Specifying the Performance and TestEN62040-3 / IEC62040-3



Output 220V/208V/220VAC


ModelStandard UnitH10K2H20K2H30K2   
Long Run UnitH10K2-XLH20K2-XLH30K2-XLH40K2-XLH50K2-XLH60K2-XL
Nominal Rating (KVA)10K20K30K40K50K60K
Input
Nominal Input   voltage (V)200/208/220
Input Voltage Range   (V)166-261Vac (line-line), full load
Nominal Input   Frequency (Hz)50/60
Input Frequency   Range (Hz)40-70
Bypass Voltage   Tolerance (%)Upper limit: +10%, +15%, or +20% default:   +15%;
    Lower limit: -10%, -20%, -30% or -40% default: -20%
Bypass Frequency   Tolerance (%)±10% or ±20%, default: ±10%
Input Power Factor> 0.99
Current THD at full   Linear Load (Thdi%)< 3%
Battery
Battery   VoltageStandard Unit30pcs 12V 7AH

60pcs

12V 7AH

   
Long Run Unit±192V ~ ±264Vdc, battery quantity 32-44 pcs (optional)
Temperature   Compensation (mV//Cell)- 3.0 (selectable from 0 to -5.0 around 25℃ or 30℃, or inhibit)
Battery Charger   Current (A)0-20 (adjustable)
Output
Nomminal Output   Voltage (V)200/208/220
Nominal Output   Frequency (Hz)50/60
Output Power Factor110.9110.9
THDv with 100%   Linear Load (%)<1%
Inverter Overload   Capactiy110% for 60min, 125% for 10min, 150% for 1 min
Efficiency
Online Mode   EfficiencyUp to 96.5%
ECO-Mode EfficiencyUp to 99.1%
Parallelparallel up to 6 units
Physics Characteristic
Dimensions
    (WxDxH) mm
Standard Unit300x700x1105300x810x1260    
Long Run Unit300x700x800360x800x980
Weight   (KG)Standard Unit146146194   
Long Run Unit747575115116118
General
Noise at 1m dB(A)<55dB (1 meter away) 
Altitude≤ 1500, derate power by 1% per 100m between 1500m and 300m
VentilationFront to back standard
Protection LevelIP20
General and SafetyUL 1778
EMC StandardsEN62040-2 / IEC62040-2
Method of Specifying the Performance and TestEN62040-3 / IEC62040-3